ANENG AN8002 Digital True RMS 6000 Counts Multimeter AC/DC Current Voltage Frequency Resistance Temperature Tester ℃/℉
68
Kwishyura neza bihamye

Impano zagaragajwe zishobora kugarurwa mu minsi 40 nyuma yo kubona ibintu. Impano zihariye ntizishobora kugarurwa. Impano zaguzwe hamwe na coupon zishobora guhindurwa gusa.
Impano y'ubuntu
Murakaza neza kuri Roymall, urubuga rwawe rw'impano zihariye. Turashimira cyane ubufasha bwawe, kandi turabategereza impano y'ubuntu buri guhaha. Shakisha ibyifuzo byawe kandi witegure kubona impano yawe.Politiki yo kohereza
Tuzakora neza kohereza ibintu nyuma yo kubona ibyaguzwe.Mu minsi 2, ibintu bizaba byarangiye.Mu minsi 5-7 (Kuwa mbere kugeza Kuwa gatatu), ibintu bizaba byarangiye.Kohereza kuri ibihugu byinshi bishobora gutwara igihe runaka.1. Politiki yo kugarura
Twemera gusa impano zaguzwe kuri roymall.com. Impano y'ubuntu ntishobora kugarurwa. Kugirango impano ishobore kugarurwa, igomba kuba itarakoreshwa.Nyuma yo kubona inama, subiza impano yawe.Tuzakora impano yawe mu minsi 3-5 nyuma yo kubona.Impano zihariye ntizishobora kugarurwa.Koresha service@roymall.com cyangwa Whatsapp: +86193598494712.Politiki yo kugarura
Uzahabwa impano yawe nyuma yo kuyisubiza. Amafaranga yo kohereza ntayisubizwa.Koresha service@roymall.com cyangwa Whatsapp: +8619359849471Description:
It is a Auto-ranging digital MultiMate using double-integral style A/D transform as the core.
Can be used to measures Temperature AC/DC Voltage AC/DC Current Resistance Capacitance Diode and Continuity testing temperature Frequency and Etc.
The products are battery powered they are characterized by stable function and high reliability, with the features of overload protection and LCD display for clear reading are an ideal tools for lavatory radio fans and family use.
Features:
Auto Range.
True RMS measurement.
Resistance capacitance frequency file high voltage 550V protection.
Large screen display, the maximum of 6000 words.
Sampling rate: about 3 times per second.
Temperature measuring.
Backlight display.
Data retention.
Polarity automatic recognition.
Low voltage display.
10A large current measurement MA level small current measurement Automatic shutdown.
Main measurement: AC / DC voltage, AC / DC current, resistance, capacitance.
Diode / off measurement, frequency and duty ratio measurement.
Specification:
Function | Range | Resolution | Accuracy | MAX.Value | Other |
DC Voltage | 6.000V | 0.001V | u00b1(0.5%+3) | 1000V | Input Resistance:10Mu03a9 |
60.00V | 0.01V | ||||
600.0V | 0.1V | ||||
1000V | 1V | ||||
60.00mV | 0.01mV | 600mV | |||
600.0mV | 0.1mV | ||||
AC Voltage | 6.000V | 0.001V | u00b1(1.0%+3) | 750V | Input Resistance:10Mu03a9(600mV range, >60Mu03a9) Frequency Response: 40Hz-1kHz |
60.00V | 0.01V | ||||
600.0V | 0.1V | ||||
750V | 1V | ||||
60.00mV | 0.01mV | 600mV | |||
600.0mV | 0.1mV | ||||
DC Current | 6.000A | 0.001A | u00b1(1.2%+3) | 10A | MAX.Current: 10A(no more than 15 seconds) No Voltage input at this mode Frequency Response(AC): 40Hz-1kHz |
10.00A | 0.01A | ||||
60.00mA | 0.01mA | 600mA | |||
600.0mA | 0.1mA | ||||
AC Current | 6.000A | 0.001A | u00b1(1.5%+3) | 10A | |
10.00A | 0.01A | ||||
60.00mA | 0.01mA | 600mA | |||
600.0mA | 0.1mA |
Resistance | 600.0u03a9 | 0.1u03a9 | u00b1(0.5%+3) | 60Mu03a9 | No Voltage input at this mode | |||||
6.000ku03a9 | 0.001ku03a9 | |||||||||
60.00ku03a9 | 0.01ku03a9 | |||||||||
600.0ku03a9 | 0.1ku03a9 | |||||||||
6.000Mu03a9 | 0.001Mu03a9 | |||||||||
60.00Mu03a9 | 0.01Mu03a9 | u00b1(1.5%+3) | ||||||||
Capacitance | 9.999nF | 0.001nF | u00b1(5.0%+20) | 9.999mF | No Voltage input at this mode | |||||
99.99nF | 0.01nF | u00b1(2.0%+5) | ||||||||
999.9nF | 0.1nF | |||||||||
9.999u03bcF | 0.001u03bcF | |||||||||
99.99u03bcF | 0.01u03bcF | |||||||||
999.9u03bcF | 0.1u03bcF | |||||||||
9.999mF | 0.001mF | u00b1(5.0%+5) | ||||||||
Frequency | 99.99Hz | 0.01Hz | u00b1(0.1%+2) | 9.999MHz | ||||||
999.9Hz | 0.1Hz | |||||||||
9.999kHz | 0.001kHz | |||||||||
99.99kHz | 0.01kHz | |||||||||
999.9kHz | 0.1kHz | |||||||||
9.999MHz | 0.001MHz | |||||||||
Duty Cycle | 1%~99% | 0.1% | u00b1(0.1%+2) | |||||||
Diode | u221a(DC forward current is 5mA, voltage is 3V) | No Voltage input at this mode | ||||||||
Continuity | u221a(no more than 50u03a9) | |||||||||
Temperature | -20~1000u2103 | 1u2103 | u00b1(2.5%+5) | 1000u2103 | ||||||
-4~1832u2109 | 1u2109 | 1832u2109 |
Measurement mode: double-integral style A/D transform
Sample rate: 3 times per second
Over range indication: OL
Powered by 2 x AAA batteries (Not included).
Working Environment: 0-40 degrees relative humidity: <80%
Product size: approx. 130 x 65 x 30mm/5.11 x 2.55 x 1.18""
Net weight: approx. 170g
Gross weight: approx.238g
Special note: (when the digital multimeter is in the millivolt position, the value jumps.)
Millivolts value jump is a normal phenomenon.
The display of the multimeter MV gear is not 0, mainly the following.
1: If the ambient temperature and humidity in the air change too much.
2: There is a strong electric field or magnetic field interference around.
3: The multimeter itself has failed.
When the MV gear of multimeter appears to be non-zer"o, it can be judged as follows:
Dial the multimeter to the mV position.The corresponding input hole is inserted into the red and black pen line.Directly connect the red and black test leads.At this time, the multimeter displays "0000" to judge that the non-return phenomenon of the multimeter is due to environmental factors. The non-return to zer"o in this state does not affect the use of the multimeter, but it is recommended to eliminate environmental interference factors so as not to affect the measurement accuracy and produce erroneous measurements result.
Package included:
1 x ANENG AN8002 Digital Ture RMS 6000 Counts Multimeter
1 x Test Lead Set( Showing as Pictures)
1 x Test Probe
1 x Test Probe
1 x Temperature Sensing Cable
1 x Storage Bag
1 x English User Manual
Detail Pictures:
Detail Pictures: